Possible Causes
Faulty Blend Door Actuator Motor
Blend Door Actuator Motor harness is open or shorted
Blend Door Actuator Motor circuit poor electrical connection
Faulty Electric Manual Temperature Control (EMTC) Module or Electronic Automatic Temperature Control (EATC) Module
الأسباب المحتملة
Possible Symptoms
Engine Light ON (or Service Engine Soon Warning Light)
الأعراض المحتملة
Description
Under normal operation, to rotate the mode door actuator clockwise, the Electric Manual Temperature Control (EMTC) Module or Electronic Automatic Temperature Control (EATC) Module supplies voltage to the Blend, Floor/Defrost and Panel mode door actuator motors through the door actuator feed B circuits, and supplies ground through the door actuator feed A circuits. To rotate the mode door actuator counterclockwise, the EMTC module or EATC module reverses the voltage and ground circuits.
The mode door actuator feedback resistors are supplied a ground from the EMTC module or EATC module by the mode door actuator return circuits and a 5-volt reference voltage on the mode door actuator reference circuits. The EMTC module or EATC module reads the voltage on the mode door actuator feedback circuits to determine the mode door actuator position by the position of the actuator feedback resistor wiper arm.