Possible Causes
Faulty Starter Generator Control Module
Starter Generator Control Module harness is open or shorted
Starter Generator Control Module circuit poor electrical connection
الأسباب المحتملة
Possible Symptoms
Engine Light ON (or Service Engine Soon Warning Light)
الأعراض المحتملة
Description
The generator control module also called the starter generator control module is comprised of the following three control modules; the hybrid powertrain control module, 14 volt power module and the drive motor control module. These three control modules are non serviceable and are part of the generator control module.
The 14V power module has 2 internal current sensors, one for input and one for output current measurements. The 14 volt power module monitors both input and output current, and then makes a correlation between them. This diagnostic will check range performance malfunctions of one or both of the current sensors. These current sensors are internal to the 14V power module and are not serviced separately from the generator control module.