Possible Causes
Program Power Inverter Module
Faulty Power Inverter Module
Power Inverter Module harness is open or shorted
Power Inverter Module circuit poor electrical connection
الأسباب المحتملة
Possible Symptoms
Engine Light ON (or Service Engine Soon Warning Light)
الأعراض المحتملة
Description
The power inverter module, also called the drive motor generator power inverter module, contains three motor control modules and the hybrid powertrain control module. Two of the motor control modules operate their respective drive motor generator based upon power inverter module commands. The third motor control module controls the auxiliary transmission fluid pump motor. The motor control modules and the hybrid powertrain control module are part of the power inverter module and are not serviced separately.
Each motor control module measures hybrid battery high voltage with several internal sensors. The motor control modules test for loss of isolation between either the high-voltage positive circuit or high-voltage negative circuit and vehicle chassis. The motor control modules test for isolation when the high-voltage contactor relays are closed. The hybrid powertrain control module 2 only tests the hybrid battery assembly for high-voltage loss of isolation when the high-voltage contactor relays are open.
Motor control module loss of isolation is detected through the use of two high-impedance resistors and voltage measuring circuitry. The two resistors are connected in series between the high- voltage positive and high-voltage negative circuits. The centre connection of the two resistors is also connected to vehicle chassis. The motor control module then measures the voltage drop across one of the resistors. Without a loss of isolation, the motor control module should measure about half of the high voltage potential. This is referred to as mid-pack voltage. The mid-pack voltage value is then doubled by the software and displayed on a scan tool as Motor 1 Isolation Voltage, Motor 2 Isolation Voltage or Auxiliary Transmission Fluid Pump Isolation Voltage. When a loss of isolation is present, the motor isolation voltage display will indicate voltage that is more or less than actual hybrid battery high voltage. The motor control module monitors the loss of isolation voltage measuring circuitry for correct operation.